PR570 Variable Isolation Transformer & Safety Analyzer



Overview

The PR570 POWERITE II™ Variable Isolation Transformer & Safety Analyzer is an AC safety supply designed to insure that every factor related to AC power is correct. The operation is simplified, and all of the features necessary to meet these needs are included in a single, compact instrument.

Every device serviced should be checked to insure that exposed metal parts do not pose a shock hazard to the user. Safety tests are recommended by all equipment manufacturers. The PR570 safety tests are easy to interpret and perform.


Features

PR570 Powerite II™ Features:

check Insure your safety and the safety of your test instruments
check Conquer AC power source problems plus startup, shutdown, and regulator failures with a digitally accurate and variable 0-140 volt AC supply
check Have complete confidence that your AC line is right with the AC line monitor
check An adjustable current trip feature minimizes expensive parts damage by automatically removing AC power when excessive current is being drawn
check Watch voltage levels and current draw with simultaneous current and voltage displays
check Test AC outlets with an exclusive receptacle checker to ensure correct earth grounding for highest level of safety
check Protect your customers from electrical shock and protect your business from lawsuit with an automatic, auto-toggling AC line and safety ground leakage test (leakage to 10 microAmps)


Specifications

PR570 POWERITE II Variable Isolation Transformer & Safety Analyzer
Isolated Output
Voltage:0-140 VAC typical at 117 VAC input, continuously variable
Current:

3 amps continuous; 3-4 amps, 470 watts maximum intermittent use (5 minutes on, 5 minutes off)
Output Loading:Less than 12 volts drop in output with 3 amp load at 120 VAC
  
AC Volts Functions:
AC Line Voltage Tests:Measures and displays the selected voltage: Hot to External Earth Ground, Hot to Safety Ground or Hot to Neutral
Range:0-150 VAC
Accuracy:± 3% reading ±2 counts, calibrated at 117 VAC
Resolution:1 volt
Protection:240 VAC
Isolated Output Voltage:Measures and displays voltage at isolated output. Same as Line Voltage Tests.
  
Output Current Monitor:
Measurement:True Power
Range:0 to 470 watts
Accuracy:± 5% of reading, ±2 counts
Resolution:1 watt
  
Adjustable Current Trip:
Range:0-4 amps
Accuracy:±10% of reading, ±20 mA
Resolution:Adjustable in 10 mA increments
Trip Time:0.3 seconds maximum with 200% overload
  
Hot Chassis Test:
Measurement:Ties high and low lead of primary together and measures leakage to exposed metal with power off
Range:0 to 1999 µA
Accuracy:±3% of reading, ±2 counts
Resolution1 µA
Protection:150 mA RMS, 150 V maximum
  
Safety Leakage Test:
Measurement:


Referenced to either side of isolated output jack (Automatically toggles high and low line and opens and closes safety ground and displays highest reading.)
Range:0 to 1999 µA
Accuracy:±3% of reading, ±2 counts
Resolution:1 µA
Protection:150 mA RMS, 150 V maximum
Cal Check:100 µA, ±3% of reading, ±2 counts with isolated output at 120 VAC
  
Protection:
AC Input:4 amps, type 3AG slo-blo fuse
Isolated Output:Adjustable current trip, 1 to 4 Amps
  
GENERAL  
Size:6" x 11.5" x 12" (HWD)
Weight:22 lbs. (10 kg)
Power:105 to 125 VAC, 60 Hz, 4 amps idle current with no output load
  
  
phone 1.800.736.2673International 1.605.339.0100
  

Options



Accessories