PR570 Variable Isolation Transformer & Safety Analyzer
The PR570 Powerite II is a six-way safety analyzer
1. AC Receptacle Tester & Voltage Monitor
2. AC Variable Power Supply
3. Isolation Transformer
4. Output Current/Power Monitor
5. Output Circuit Breaker
6. Safety Leakage Tester
Overview
The PR570 POWERITE II™ Variable Isolation Transformer & Safety Analyzer is an AC safety supply designed to insure that every factor related to AC power is correct. The operation is simplified, and all of the features necessary to meet these needs are included in a single, compact instrument.
Every device serviced should be checked to insure that exposed metal parts do not pose a shock hazard to the user. Safety tests are recommended by all equipment manufacturers. The PR570 safety tests are easy to interpret and perform.
Features
PR570 Powerite II™ Features:
Specifications
| Isolated Output | |
| Voltage: | 0-140 VAC typical at 117 VAC input, continuously variable |
| Current: | 3 amps continuous; 3-4 amps, 470 watts maximum intermittent use (5 minutes on, 5 minutes off) |
| Output Loading: | Less than 12 volts drop in output with 3 amp load at 120 VAC |
| AC Volts Functions: | |
| AC Line Voltage Tests: | Measures and displays the selected voltage: Hot to External Earth Ground, Hot to Safety Ground or Hot to Neutral |
| Range: | 0-150 VAC |
| Accuracy: | ± 3% reading ±2 counts, calibrated at 117 VAC |
| Resolution: | 1 volt |
| Protection: | 240 VAC |
| Isolated Output Voltage: | Measures and displays voltage at isolated output. Same as Line Voltage Tests. |
| Output Current Monitor: | |
| Measurement: | True Power |
| Range: | 0 to 470 watts |
| Accuracy: | ± 5% of reading, ±2 counts |
| Resolution: | 1 watt |
| Adjustable Current Trip: | |
| Range: | 0-4 amps |
| Accuracy: | ±10% of reading, ±20 mA |
| Resolution: | Adjustable in 10 mA increments |
| Trip Time: | 0.3 seconds maximum with 200% overload |
| Hot Chassis Test: | |
| Measurement: | Ties high and low lead of primary together and measures leakage to exposed metal with power off |
| Range: | 0 to 1999 µA |
| Accuracy: | ±3% of reading, ±2 counts |
| Resolution | 1 µA |
| Protection: | 150 mA RMS, 150 V maximum |
| Safety Leakage Test: | |
| Measurement: | Referenced to either side of isolated output jack (Automatically toggles high and low line and opens and closes safety ground and displays highest reading.) |
| Range: | 0 to 1999 µA |
| Accuracy: | ±3% of reading, ±2 counts |
| Resolution: | 1 µA |
| Protection: | 150 mA RMS, 150 V maximum |
| Cal Check: | 100 µA, ±3% of reading, ±2 counts with isolated output at 120 VAC |
| Protection: | |
| AC Input: | 4 amps, type 3AG slo-blo fuse |
| Isolated Output: | Adjustable current trip, 1 to 4 Amps |
| GENERAL | |
| Size: | 6" x 11.5" x 12" (HWD) |
| Weight: | 22 lbs. (10 kg) |
| Power: | 105 to 125 VAC, 60 Hz, 4 amps idle current with no output load |
| phone 1.800.736.2673 | International 1.605.339.0100 |