SP495 SoundPro Audio Consultant



Overview

The Audio Consultant is a powerful acoustic analyzer for design/consultation. It provides acoustic/audio analysis for analyzing distributed sound, sound reinforcement systems, live sound applications and industrial sound analysis; all in one handheld, battery-operated instrument.

The SP495 features Noise Curves, Multi-Band Decay analysis, Time Delay Analysis (TDA), TerraLink software for 3D graph analysis, Speech Intelligibility, electrical audio tests (Tech Bench) and digital output to S/PDIF, Toslink, and USB ports. An Impulse Recorder, or Stereo Recorder, records audio inputs to memory (wav) files. Files can be stored to an SD memory card.

The SP495 features a color LCD display, dual phantom-powered high-gain/low-distortion microphone inputs, powerful dual-FFT processing, integrated USB audio interface, and independent analog monitoring. Supplied accessories are a Type 2 standard measurement microphone, XLR cable, USB cable, impedance test cable, power adapter/charger, battery and carrying case.


Features

Here's What the SoundPro Audio Consultant Delivers:

check Fast and accurate adjustments of speaker coverage and cluster alignment, time delays and speaker frequency response equalization to ensure a high-performance, problem free installation.
check Portable, handheld (5 hours battery run time) in a ruggedized case means you can conveniently make precise audio system measurements wherever you do commercial audio work.
check High resolution color LCD, 1/30 octave FFT Analyzer, high-res ETG, bi-directional stereo audio USB interface, digital audio LPCM outputs (S/PDIF, Toslink & USB), and high level analog audio outputs.
check Impulse Recorder records room impulse response for transfer to acoustic analysis programs.
check SD memory card for transferring Recorder wav files, plus graphical and textual memory test data.
check Macro function records and plays back a timed series of user-input control actions.
check Auto HT and Auto Polarity Test compatibility with DAG5161 Multichannel Digital Audio Generator.
check Optional firmware add-ons - TechBench (electrical signal/component tests), Speech Intelligibility (ALCONS, RaSTI, STI-PA), Time Delay Analysis (TDA), NoiseCurves (NC, RC, PNC) with overlaid RTA noise curves, Transmission Loss (STC, NIC), Multi-Band Decay, and Audio Stethoscope; you'll never be caught short.

Specifications

SP495 SoundPro Audio Consultant Specifications
SPL: Measures ambient sound energy levels at microphone input, displays true RMS SPL
Averaging:Meets ANSI S1.4, Slow, Fast, Impulse, Peak, Avg-Equal time-averaged SPL
Range:25 - 105 dBA with supplied mic
 25 - 146 dBA with precision mic
Accuracy:±0.3 dB, steady state
Resolution:0.1 dB
  
Signal Generator: Signals: Pink, white, sine, square, impulse, sine sweep, log-swept sine sweep
Range:20 Hz - 20 kHz
Level:-35 dBu to 17 dBu
Flatness:±0.05 dB, 20 Hz - 20 kHz
THD:< 0.01% at full-scale sine output
  
Real-Time Analyzer, FFT Analyzer: Plots sound energy levels vs. octave band-filtered spectrum
Level Range:25 - 105 dBA with supplied mic
 25 - 146 dBA with precision mic
Level Accuracy:±0.5 dB with supplied mic
Level Resolution:±0.5 dB
Frequency Range:20 Hz to 20 kHz
Frequency Accuracy:± 1%
  
Level/Frequency Meter: Stereo level meter reads in dBu,dBv, Vp-p, Vrms, or dBr (reference)
Level Range:+40 dBu to -85 dBu
Level Accuracy:±0.5 dB from 20 Hz to 20 kHz
Frequency Range:20 Hz to 20 kHz
Frequency Accuracy:±1 Hz
  
Energy-Time Graph (ETG): Graphs impulse sound decay energy vs. time or distance; Identifies arrival time of direct sound and audio reflections; Displayed in mS (milliseconds), ft (feet), m (meters)
Range:From 0 mS to 7680 mS
Accuracy:Better than ± 1% of full scale
Resolution:± 1% graph pixel
  
Impedance Meter: Measures the impedance of an audio device (frequency of the test is variable); Indicates watts or amplification required at a particular voltage
Accuracy/Range:1 ohm to 50 ohms, ± 2%, 50 Hz - 12.5 kHz
Accuracy/Range:1 ohm to 4.5 kohms, ±10%, 20 Hz - 20 kHz
  
Reverb Decay Time: Calculates time for residual pink noise test signal to decay 60 dB in room; also RT10, RT20
Range:0 to 15 Sec.
Accuracy:± 2% of full signal
Resolution:10 mSec.
Weighting Networks:A, C, Flat, octave, or 1/3-octave band filtered
  
Distortion Meter (THD/IMD): Measures distortion of an incoming signal; performs SMPTE IMD and DIN IMD tests
THD+N:Computes Total Harmonic Distortion plus Noise
Range:0.02% to 50% THD+N
IMD:Computes Inter-Modulation Distortion
Inputs:Speaker, microphone, line level
Accuracy:±5% of reading
  
Audio Scope: Is an audio-bandwidth digital oscilloscope; works with either or both of the inputs; looks for audio waveforms, identifies audio distortion, clipping, and polarity problems; provides a good graphical representation of the audio wave shape.
Sample rate:48 kHz
Accuracy:±1 display pixel
  
Polarity Test: Provides a simple, reliable way of determining absolute polarity of all loudspeaker drivers; applies pulses to the amplifier and loudspeakers and compares the polarity of the reproduced pulses picked up by the microphone to the polarity of the applied pulses.
Range:0 to 500 feet, speaker to mic
 Shows polarity of mid-frequency wave front
  
Supplied Microphone: Provides a simple, reliable way of determining absolute polarity of all loudspeaker drivers; applies pulses to the amplifier and loudspeakers and compares the polarity of the reproduced pulses picked up by the microphone to the polarity of the applied pulses.
Range:0 to 500 feet, speaker to mic
 Shows polarity of mid-frequency wave front
  
STANDARDS
Sound Level Meter:ANSI S1.4-1983 (ASA47-1983)
Leq:ANSI S1.43-1997
Dosimeter:ANSI S1.25-99 (ASA 98-1991) Class 2
Digital Filters:ANSI S1.11-1986 1/1, 1/3 octave digital filters
All filters, weighting networks, response rates, and algorithms meet or exceed ANSI Type 1 specifications.
  
Power:
Battery:Li-Ion pack provides 2-3 hours of service, depending on usage
AC adapter/charger:120/130/230/240 VAC, 9-12 VDC, 800 mA (nominal 9V)
  
General:
Input Impedances
XLR and balanced inputs:40 kohms
RCA unbalanced inputs:20 kohms
  
Output Impedances
XLR and balanced outputs:300 ohms
RCA unbalanced outputs:150 ohms
  
Size:5.5" x 12.5" x 2.25" (HWD)
Weight:2 lb. 5 oz.
  
  
  
mailto:sales@sencore.com
phone 1.800.736.2673International 1.605.339.0100
  

Options



Accessories