SP495 SoundPro Audio Consultant
Overview
The Audio Consultant is a powerful acoustic analyzer for design/consultation. It provides acoustic/audio analysis for analyzing distributed sound, sound reinforcement systems, live sound applications and industrial sound analysis; all in one handheld, battery-operated instrument.
The SP495 features Noise Curves, Multi-Band Decay analysis, Time Delay Analysis (TDA), TerraLink software for 3D graph analysis, Speech Intelligibility, electrical audio tests (Tech Bench) and digital output to S/PDIF, Toslink, and USB ports. An Impulse Recorder, or Stereo Recorder, records audio inputs to memory (wav) files. Files can be stored to an SD memory card.
The SP495 features a color LCD display, dual phantom-powered high-gain/low-distortion microphone inputs, powerful dual-FFT processing, integrated USB audio interface, and independent analog monitoring. Supplied accessories are a Type 2 standard measurement microphone, XLR cable, USB cable, impedance test cable, power adapter/charger, battery and carrying case.
Features
Here's What the SoundPro Audio Consultant Delivers:
Specifications
| SPL: Measures ambient sound energy levels at microphone input, displays true RMS SPL | |
| Averaging: | Meets ANSI S1.4, Slow, Fast, Impulse, Peak, Avg-Equal time-averaged SPL |
| Range: | 25 - 105 dBA with supplied mic |
| 25 - 146 dBA with precision mic | |
| Accuracy: | ±0.3 dB, steady state |
| Resolution: | 0.1 dB |
| Signal Generator: Signals: Pink, white, sine, square, impulse, sine sweep, log-swept sine sweep | |
| Range: | 20 Hz - 20 kHz |
| Level: | -35 dBu to 17 dBu |
| Flatness: | ±0.05 dB, 20 Hz - 20 kHz |
| THD: | < 0.01% at full-scale sine output |
| Real-Time Analyzer, FFT Analyzer: Plots sound energy levels vs. octave band-filtered spectrum | |
| Level Range: | 25 - 105 dBA with supplied mic |
| 25 - 146 dBA with precision mic | |
| Level Accuracy: | ±0.5 dB with supplied mic |
| Level Resolution: | ±0.5 dB |
| Frequency Range: | 20 Hz to 20 kHz |
| Frequency Accuracy: | ± 1% |
| Level/Frequency Meter: Stereo level meter reads in dBu,dBv, Vp-p, Vrms, or dBr (reference) | |
| Level Range: | +40 dBu to -85 dBu |
| Level Accuracy: | ±0.5 dB from 20 Hz to 20 kHz |
| Frequency Range: | 20 Hz to 20 kHz |
| Frequency Accuracy: | ±1 Hz |
| Energy-Time Graph (ETG): Graphs impulse sound decay energy vs. time or distance; Identifies arrival time of direct sound and audio reflections; Displayed in mS (milliseconds), ft (feet), m (meters) | |
| Range: | From 0 mS to 7680 mS |
| Accuracy: | Better than ± 1% of full scale |
| Resolution: | ± 1% graph pixel |
| Impedance Meter: Measures the impedance of an audio device (frequency of the test is variable); Indicates watts or amplification required at a particular voltage | |
| Accuracy/Range: | 1 ohm to 50 ohms, ± 2%, 50 Hz - 12.5 kHz |
| Accuracy/Range: | 1 ohm to 4.5 kohms, ±10%, 20 Hz - 20 kHz |
| Reverb Decay Time: Calculates time for residual pink noise test signal to decay 60 dB in room; also RT10, RT20 | |
| Range: | 0 to 15 Sec. |
| Accuracy: | ± 2% of full signal |
| Resolution: | 10 mSec. |
| Weighting Networks: | A, C, Flat, octave, or 1/3-octave band filtered |
| Distortion Meter (THD/IMD): Measures distortion of an incoming signal; performs SMPTE IMD and DIN IMD tests | |
| THD+N: | Computes Total Harmonic Distortion plus Noise |
| Range: | 0.02% to 50% THD+N |
| IMD: | Computes Inter-Modulation Distortion |
| Inputs: | Speaker, microphone, line level |
| Accuracy: | ±5% of reading |
| Audio Scope: Is an audio-bandwidth digital oscilloscope; works with either or both of the inputs; looks for audio waveforms, identifies audio distortion, clipping, and polarity problems; provides a good graphical representation of the audio wave shape. | |
| Sample rate: | 48 kHz |
| Accuracy: | ±1 display pixel |
| Polarity Test: Provides a simple, reliable way of determining absolute polarity of all loudspeaker drivers; applies pulses to the amplifier and loudspeakers and compares the polarity of the reproduced pulses picked up by the microphone to the polarity of the applied pulses. | |
| Range: | 0 to 500 feet, speaker to mic |
| Shows polarity of mid-frequency wave front | |
| Supplied Microphone: Provides a simple, reliable way of determining absolute polarity of all loudspeaker drivers; applies pulses to the amplifier and loudspeakers and compares the polarity of the reproduced pulses picked up by the microphone to the polarity of the applied pulses. | |
| Range: | 0 to 500 feet, speaker to mic |
| Shows polarity of mid-frequency wave front | |
| STANDARDS | |
| Sound Level Meter: | ANSI S1.4-1983 (ASA47-1983) |
| Leq: | ANSI S1.43-1997 |
| Dosimeter: | ANSI S1.25-99 (ASA 98-1991) Class 2 |
| Digital Filters: | ANSI S1.11-1986 1/1, 1/3 octave digital filters |
| All filters, weighting networks, response rates, and algorithms meet or exceed ANSI Type 1 specifications. | |
| Power: | |
| Battery: | Li-Ion pack provides 2-3 hours of service, depending on usage |
| AC adapter/charger: | 120/130/230/240 VAC, 9-12 VDC, 800 mA (nominal 9V) |
| General: | |
| Input Impedances | |
| XLR and balanced inputs: | 40 kohms |
| RCA unbalanced inputs: | 20 kohms |
| Output Impedances | |
| XLR and balanced outputs: | 300 ohms |
| RCA unbalanced outputs: | 150 ohms |
| Size: | 5.5" x 12.5" x 2.25" (HWD) |
| Weight: | 2 lb. 5 oz. |
| mailto:sales@sencore.com | |
| phone 1.800.736.2673 | International 1.605.339.0100 |