DPI Monitor Specifications

 

 

TRANSPORT STREAM

ASI Serial TS Input/Output:

1 to 8 ASI Inputs:           BNC’s

Standard:                       EN50083-9 (V2:3/98) DVB ASI

Data Bit rate:                 270 Mbits/s (Max TS 60 Mbits/s

Max Number of Programs: 25 per transport stream

 

DPI Message Syntax:

Compatibility Standard: SCTE 35

 

Monitoring and logging of:                                 

       Begin and End date of the Avail

       Splice_insert commands count

       Event_id with interpretation of the Event source and Event_number

       Transport Stream input number

       Transport Stream ID

       Service number (PMT)

       Service Name from SDT or VCT (standard configuration set to DVB or ATSC)

       Program ID

       Avail field

       Avail count

 

MPEG-2 Transport Stream Monitoring:

Compatibility Standard: ETR 101290 Priority 1

 

Monitoring and logging of:                                

       TS sync error (TR1290 1.1)

       Sync byte error (TR1290 1.2)

       PAT time out (TR1290 1.3)

       PMT time out (TR1290 1.5)

       Continuity counter errors (TR1290 1.4)

       SCTE 35 section syntax error

       Time out on Expected PID (TR1290 1.6)

       Transport Error indicator (TR1290 2.1)

 

General Specifications:

Remote Interface: 10/100 Ethernet on RJ45

Power:                  AC Input, 100V - 240VAC

Power consumption: Normal operating - 50W,

                                  200W max

Operating Temperature: 15 to 35 degrees C

Size: Height = 1U, Width = 19", Depth = 16"

Weight: 25 pounds

 

 

For more information call:

1.800.SENCORE (1.800.736.2673)

or 1.605.339.0100

Ask for ATSC product group

mailto:sales@sencore!com

Sencore Inc.

3200 Sencore Drive

Sioux Falls, SD 57107

U.S.A.