Select a more detailed description of this product by application:
DSL757 - "DIRECTOR"TM Digital Signal Level Meter
All channel/frequency tuning from 50 to 860 MHz to meet your system testing needs now and in the future.
Auto attenuation from -35 dBmV to +60 dBmV for full signal measuring capabilities.
18 Volt (500 mA) power output with front panel access for testing and powering down-converters and decoders.
Easy-to-read bar graph of relative signal strength for quick antenna peaking and alignment.
Signal-to-Noise measurements to determine the quality of signal and identify problems with either signal or system noise.
Full signal testing capabilities that include: Video level, Audio level, C/N, and HUM.
Exclusive Peak-to-Valley measurement on digital channels.
Portable, rugged and weatherproof design that is ready for any environment with backlit LCD display for working in low light conditions.
Smart power - over six hours of continuous use on a single battery charge and is fully recharged in less that six hours. The DSL757 features both AC or DC charging capabilities.
Eight pre-programmed channel plans or easy custom channel planning capabilities to fit your system needs.
Sencore’s industry exclusive 3-year warranty.
DSL757 Condensed Specifications
TUNING RANGE
Channel Plans:
FCC (std), HRC, IRC, VHF/UHF, PAL A, PAL B/G, PAL I, Belgium, German, Israel, Japan, Cust 1 & 2
Channel Step Size: 1 CH
Frequency Step Size: 50 kHz
CATV BAND
Channels: 2 thru 134 (CH 1 in HRC & IRC)
Frequency: 50 thru 859.25 MHz
VHF + UHF BAND
Channels: 2 thru 69
Frequency: 50 thru 810 MHz
TUNING ACCURACY
Channel & Frequency: 10 PPM (&plumn; 10 kHz)
RESOLUTION
Channel Mode: 1 Channel, 1 thru 127 VHF & 14 thru 69 UHF
Frequency Mode: 50 kHz
RF INPUT
Sensitivity: - 35 dBmV
Maximum reading: + 60 dBmV
Input Impedance: 75 Ohms
Return Loss: 15 dB minimum
Max. Safe Input: 100 VDC or 100 Vrms
Do Not Exceed This Rated Voltage!
Input Impedance: 75 Ohms
Input Impedance: 75 Ohms
DIGITAL CARRIER FUNCTIONS
Selectable Digital Symbol Rates: 1 MHz, 2 MHz, 3 MHz, 4 MHz, 5 MHz, 6 MHz, 7 MHz, 8 MHz
MEASUREMENT DYNAMIC RANGES
1 MHz Range: -29.5 dBmV to +65.3 dBmV
2 MHz Range: -26.5 dBmV to +68.5 dBmV
3 MHz Range: -24.7 dBmV to +70.3 dBmV
4 MHz Range: -23.5 dBmV to +71.5 dBmV
5 MHz Range: -22.5 dBmV to +72.5 dBmV
6 MHz Range: -21.7 dBmV to +73.3 dBmV
7 MHz Range: -21.0 dBmV to +74.0 dBmV
8 MHz Range: -20.4 dBmV to +74.6 dBmV
DIGITAL LEVEL MEASUREMENTS
Divides digital channels into 500 kHz segments, measures the signal level at the center frequency
of each segment, then calculates the signal level of the whole channel using the information from
these segment levels.
DIGITAL PEAK TO VALLEY FUNCTION
Divides digital channels into 500 kHz segments, measures the signal level at the center frequency
of each segment, then displays the difference between the highest and lowest segment levels.
VIDEO AND AUDIO CARRIER LEVELS
Amplitude Resolution: 0.1 dB
AMPLITUDE ACCURACY
CATV and VHF/UHF:
± 1.0 dB, Flatness 5 to 750 MHz
± 1.0 dB, Level Linearity -35 to +60 dBmV
Typical: ± 1.5 dB Total, @ 70°F
AMPLITUDE ACCURACY
CW vs Modulated vs Scrambled: ± 0.25 dB
AUDIO/VIDEO CARRIER RATIO A/V
Amplitude Resolution: 0.1 dB
Amplitude Accuracy: ± 1 dB
AMPLITUDE VARIATION OVER TEMPERATURE
All Bands:
± 2.5 dB, 15°F to 120°F
± 3 dB, < 15°F, > 120°F
Amplitude Resolution: 0.1dB
Amplitude Accuracy: ± 1 dB
HUM MEASUREMENT
Input: > -10 dBmV, Modulated Video or CW carrier
Measurement Range: 0.5 to 10.0%
Display Resolution: 0.1%
Measurement Accuracy:
0.5%, from 0.5 to 5%
1%, from 5% to 10%
C/N RATIO
Automatic Off Channel Test
Amplitude Resolution: 0.1 dB
Amplitude Accuracy: ± 1 dB
RANGE
Input Level: 20 dBmV provides 44 dB of range
LNB SUPPLY POWERING
18 Volts at 500 mA minimum
GENERAL
Power Requirements: 120 VAC, 12 VDC Rechargeable Battery Life: 6 hrs continuous
Battery Saver Time-out: 10 min. nominal
Battery Charge Time: 6 Hr.
Charger: 14 V at 700 mA (12.0 V min, 17 V max)
Size: 10.4" H x 6.0" W x 2.4" D
Weight: < 3.5 lb.
ENVIRONMENTAL
Operating Temperature: -0°F to +120°F
Storage Temperature: -40°F to +150°F
Humidity: 0 to 90% (non-condensing)
Water Resistant: Water on any surface (Not Rated Submersible)
ACCESSORIES SUPPLIED WITH UNIT
AC Charger/Adapter
12 VDC Vehicle Charger/Adapter
3’ RG-59 Test Cable
OPTIONAL ACCESSORIES (NOT SUPPLIED)
Padded Case
Sky Hooks
20 dB Test Probe
[Sencore Home Page]