![[product image]](/products/images/ha2500_2.jpg)
As Low As $100 Per
Month!
HA2500 Universal Horizontal Analyzer Features
|
Unique frequency lock and variable horizontal frequency use allows you to quickly service all horizontal circuits no matter the frequency |
|
Exclusive "Horizontal Output Load Test" makes setup and testing a snap - even without applying AC power for more accurate estimates, fewer damaged replacement parts, and faster diagnosis and repair |
|
Patented "ringer" proves the condition of flybacks and yokes in seconds - even a single shorted turn |
|
Exclusive "Dynamic Tests" help you analyze the horizontal circuit in powered-up conditions to catch even subtle defects in the power supply, noise, and drive signal |
|
Variable-current limited & protected B+ substitute power supply permits testing of horizontal stages even when the power supply is dead |
|
Portable and field rugged to go on location when bringing the defective product to your bench isn't feasible |
HA2500 Condensed Specifications
HORIZONTAL FREQUENCY GENERATOR FUNCTION: - Squarewave generator for Load Tests and Sub Drive functions. FREQUENCY RANGE: 15 kHz to 125 kHz |
EXTERNAL SYNC INPUT: INPUT SIGNALS: - Horizontal Sync, Composite Sync, Composite Analog Video (± Polarity) FREQUENCY RANGE: 15 kHz - 125 kHz SENSITIVITY: Composite Analog Video > .5 VPP Horiz. or Composite Sync > 2 VPP |
HORIZONTAL OUTPUT LOAD TEST B+ POWER SUPPLY VOLTAGE RANGE: - 0 - 18 VDC ± 0.5 volts. CURRENT LIMIT: 250 mA ± 10% |
HORIZONTAL OUTPUT LOAD TEST SETUP EXCITATION DRIVE: Squarewave 50% duty cycle ± 2% B+ VOLTS RANGE: 0 - 19.9 volts VPP RANGE: autoranged 0 - 400 VPP |
HORIZONTAL OUTPUT LOAD TESTS B+ mA RANGE: 0 - 250 mA TIME µS RANGE: 0.1 µS - 50 µS TIME µS TRIGGER LEVEL: 5% ± 1% of pos. pulses with VPP > 10 VPP |
RINGER TEST FUNCTION: Approximate coil "Q" determined by exciting the coil and counting ringing cycles to a damped level. |
DYNAMIC TESTS (Collector or Drain Meter) VDC RANGE: Autoranged, 0- 400 volts VPP RANGE: Autoranged, 0 VPP to 1500 VPP TIME µS RANGE: 0 - 50 µS TIME µS TRIGGER LEVEL: 5% ± 1% of pulse VPP >20 VPP |
DYNAMIC TESTS (Base or Gate Meter) VPP RANGE: 0 VPP to 50 VPP |
DYNAMIC TESTS (Horizontal Driver Test) FUNCTION: Measures the horizontal driver stage output current capability by simulating a low impedance base/emitter transistor junction. BASE mA RANGE: 0 - 2000 mA |
DYNAMIC TESTS (Sub Drive) FUNCTION: Substitute drive optimized to properly drive the base or gate of any horizontal output transistor. BASE SUB OUTPUT: Squarewave 50%, -2/+6% duty cycle GATE SUB OUTPUT: Squarewave, 50% duty cycle ±2% |
SUBSTITUTE B+ SUPPLY VOLTAGE RANGE: 30 volts to 180 volts POWER OUPUT: 2 amps ± 10% to 40 volts, 80 watts ± 10% over 40 volts POWER LIMIT RANGE: 3 watt (min.) to 80 watt |
GENERAL FLOATING GROUND ISOLATION: 600 volts (DC + peak AC) from "-" terminal to chassis ground with 500 µA DIGITAL DISPLAY: Vacuum fluorescent matrix, 40 x 2 AC POWER: 105 to 125 VAC 50/60 Hz. May be factory converted to 220 VAC. SIZE: 6" X 11.5" X 15.5" (15.2 X 29.1 X 39.3 cm) HWD WEIGHT: 14 lbs. (6.4 kg.) |
| All specifications allow for 20 minutes of warm-up and are guaranteed at 15 to 35 degrees C. |
[Sencore Home Page]
email webmaster@sencore.com for feedback on our site. Or call 1-800-SENCORE (736-2673)/1-605-339-0100 Copyright © 1997 Sencore, Inc. All rights reserved.
|