On GSA Contract
GS-24F-0812A
LC103 - "ReZolver"TM In-Circuit Capacitor/Inductor Analyzer
 |
Pinpoints bad capacitors and inductors "in-circuit," and automatically tells you when further out-of-circuit tests are required.
|
 |
Analyzes capacitors for all four failures out-of-circuit: - Value from 1 pF to 20 F - Equivalent series resistance - Leakage with up to 1,000 volts applied - Dielectric absorption
|
 |
Tests SMT components "in-circuit" and accurately with exclusive, time-saving test accessories.
|
 |
Analyzes inductors with exclusive patented tests for: - Values from 0.1 uH to 20 H - Opens or shorts - Even one shorted turn with patented "Ringer" test
|
 |
Makes all tests, compares the results to EIA standards, and tells you "GOOD" or "BAD" - automatically.
|
 |
Tests SCRs and triacs with optional SCR250 accessory.
|
LC103 Condensed Specifications
IN-CIRCUIT TESTS (Capacitors and Inductors): - Dynamic in-circuit tests to determine whether the component is good or bad. Component Types: Electrolytic, double layer lytic, tantalum, ceramic, and other capacitors. Yokes, flybacks, switching transformers, and coils. Inductor Range: 3.18 uH to 3.18 H Capacitor Range: 0.002 uF to 20,000 uF Accuracy: Same as Out-of-Circuit tests for known good inductors and capacitors with no parallel current paths. Suggest Removal Indication: Initiated when AC test differs from DC test by more than 20%, or if low level DCR test indicates a leakage path greater than 20% of charge current for capacitors.
CAPACITORS (Out-of-Circuit): Value: Dynamic test of capacity value is determined by applying a constant current to the capacitor and measuring the dV/dt. Range: 1 pF to 20 F Accuracy: ±1%, ±1 pF, ±1 digit for values to 1990 uF, ±5%; ±0.1% of range full scale for values 2000 uF to 20 F
EQUIVALENT SERIES RESISTANCE (ESR): Accuracy: ±5%, ±1 digit Capacitor Range: 0.01 uF to 20 F
DIELECTRIC ABSORPTION: Accuracy: ±5% of reading, ±1 count Range: 1 to 100% Capacitor Range: 0.01 uF to 20 F
LEAKAGE: Accuracy: ±5%, ±1 digit Applied Voltage: Keyboard entry 1.0 to 1000 volts in 0.1 volt steps short circuit current limited to 900 mA
INDUCTORS (Out-of-Circuit): Value: A dynamic test of value determined by measuring the EMF produced when a changing current is applied to the coil under test Range: 0.1 uH to 20 H Accuracy: ±2%, ±1 digit, ±0.1 uH
RINGING TEST: - A dynamic test of inductor quality determined by applying an exciting pulse to the inductor and counting the number of cycles the inductor rings before reaching a preset damping point. Inductor Range: 10 uH and larger, non-iron core Accuracy: ±1 count on readings between 8 and 13 Rings Resolution: ±1 count Exciting Pulse: 5 volts peak
GENERAL: Temperature Operating Range: 32¡ to 104¡ F (0¡ to 40¡ C) Temperature Range for Specified Accuracy (after 10 minute warm-up): 50¡ to 86¡ F (10¡ to 30¡ C) Power: 105-130V AC, 60Hz, 30 watts with supplied PA251 power adapter. Battery operation with optional BY289 rechargeable battery. Auto-Off: Removes power during battery operation if unit sits idle longer than 5 minutes. Battery Life: 2 hours typical operation HxWxD Size: 6" x 9" x 11.5" (15.2 cm x 22.9 cm x 29.l cm) Weight: 6.0 lbs. (2.7 kg) without battery, 7.6 lbs. (3.4 kg) with battery GOOD/BAD Indication: Functions on all tests. Requires user input of component type and value, or input of desired limits.
All specifications subject to change without notice.