{PR570}

[product image]
As Low As $100 Per Month!



Call 1-800-SENCORE and ask about our new Safety Leakage Promo Pak.

On GSA Contract

Insure your safety and the safety of your test instruments whenever servicing electronic products


 

Conquer AC power source problems plus startup, shutdown, and regulator failures with a digitally accurate and variable 0-140 volt AC supply

Have complete confidence your AC line is right with the AC line monitor

An adjustable current trip feature minimizes expensive parts damage by automatically removing AC power when excessive current is being drawn

Watch voltage levels and current draw with simultaneous current and voltage displays

Test AC outlets with an exclusive receptacle checker to ensure correct earth grounding for the highest level of safety

Protect your customers from electrical shock and protect your business from lawsuit with an automatic, auto-toggling AC line and safety ground leakage test (leakage to 10 microamps)

PR570 Condensed Specifications

Isolated Output - VOLTAGE: 0-140 VAC typical at 117 VAC input, continuously variable. CURRENT: 3 amps continuous; 3-4 amps, 470 watts maximum intermittent use (5 minutes on, 5 minutes off). OUTPUT LOADING: Less than 12 volts drop in output with 3 amp load at 120 VAC.

AC Volts Functions - AC LINE VOLTAGE TESTS: Measures and displays the selected voltage: Hot to External Earth Ground, Hot to Safety Ground or Hot to Neutral. RANGE: 0-150 VAC. ACCURACY: ±3% reading ±2 counts, calibrated at 117 VAC. RESOLUTION: 1 volt. PROTECTION: 240 VAC. ISOLATED OUTPUT VOLTAGE: Measures and displays voltage at isolated output. Same as Line Voltage Tests.

Output Current Monitor - MEASUREMENT: True Power. RANGE: 0 to 470 watts. ACCURACY: ±5% of reading, ±2 counts. RESOLUTION: 1 watt.

Adjustable Current Trip - RANGE: 0-4 amps. ACCURACY: ±10% of reading, ±20 mA. RESOLUTION: Adjustable in 10 mA increments. TRIP TIME: 0.3 seconds max. with 200% overload.

Hot Chassis Test - MEASUREMENT: Ties high and low lead of primary together and measures leakage to exposed metal with power off. RANGE: 0 to 1999 µA. ACCURACY: ±3% of reading, ±2 counts. RESOLUTION: 1 µA. PROTECTION: 150 mA RMS, 150 V max.

Safety Leakage Test - MEASUREMENT: Referenced to either side of isolated output jack. (Automatically toggles high and low line and opens and closes safety ground and displays highest reading.) RANGE: 0 to 1999 µA. ACCURACY: ±3% of reading, ±2 counts. RESOLUTION: 1 µA. PROTECTION: 150 mA RMS, 150 V max. CAL CHECK: 100 µA, ±3% of reading, ±2 counts with isolated output at 120 VAC.

Protection - AC INPUT: 4 amps, type 3AG slo-blo fuse. ISOLATED OUTPUT: Adjustable current trip, 1 to 4 amps.

General - SIZE: 6" x 11.5" x 12" (15.2 x 25.4 x 29.2 cm) HWD. WEIGHT: 22 lbs. (10 kg). POWER: 105 to 125 VAC, 60 Hz, 4 amps idle current with no output load.


[Sencore Home Page]

email webmaster@sencore!com for feedback on our site.
Or call 1-800-SENCORE (736-2673)/1-605-339-0100
Copyright © 1997 Sencore, Inc. All rights reserved.