PSL60 - Universal
Power Supply Load
Determine if the system’s defects are in the power supply
or the load circuitry.
Simulates different power demands or "loading" on the power
supply output to duplicate symptoms
and
identify power supply problems.
Analyzes the power output capability of any power supply
that outputs 4 to 200 volts.
Analyzes the current limiting circuits of a switching power
supply to identify limiting defects.
PSL60 Condensed Specifications
LOAD RANGES
Sets the power and voltage range of the electronic load.
Ranges:
20 Watts, 4-20 Volts
20 Watts, 15-60 Volts
60 Watts, 15-60 Volts
60 Watts, 4-20 Volts (10 Amps Max.)
60 Watts, 50-200 Volts
INPUT VOLT METER
Measures input voltage to the electronic load.
Range: +0.1 - 250 Volts
Accuracy: 1%, (2 Counts)
Resolution: 0.1 Volts
LOAD CURRENT SETTINGS
Sets the current level to the electronic load.
Range: 0.01 - 10 Amps
Accuracy: 3%, (2 Counts)
Resolution (Range Dependent):
0.01 Amps to 0.99 Amps
0.1 Amps to 10 Amps
POWER METER
Indicates electronic load power (volts X current).
Range: 0.1 - 60 Watts
Accuracy: 4%, (4 Counts)
Resolution (Range Dependent):
0.1 Watt in 20 Watt Ranges
1 Watt in 60 Watt Ranges
LOAD INPUT
Volts Protection: 250 Volts DC + Peak AC
Reverse Voltage Protection: Diode
GENERAL
Digital Display: LCD Matrix
Humidity: 0-99% No Condensation
Power Requirements: 12 VDC, 300 mA Min. (may be factory converted to 220 VAC)
Size (HxWxD): 5.25" X 8" X 6.25"
Weight: Approx. 3 lbs.
All specifications subject to change without notice.
[Sencore Home Page]
email webmaster@sencore!com for feedback on our site. Or call 1-800-SENCORE (736-2673)/1-605-339-0100 Copyright © 1997 Sencore, Inc. All rights reserved.
|
|
|