SA 1454 Portable Signal Analyzer
Overview
The SA 1454 is an integrated TV/RF signal level meter, signal quality analyzer and spectrum analyzer which isolates antenna, cable, TV and RF distribution problems in minutes. The full spectral display allows you to view your full channel line-up or a specific channel or frequency for quick and accurate signal troubleshooting and verification.
The SA1454 provides signal leakage and ingress testing capabilities. In the digital world, ingress can cause serious signal delivery problems. Most signal ingress problems can be directly traced back to the consumer side of the drop.
The SA1454 can see TV/RF carriers simultaneously for fast level and tilt adjustment comparisons. It can visually inspect near or in a TV/RF channel to find interference carriers and see channel signal flatness to orient antenna for best digital TV reception.
Features
The SA 1454 Portable Signal Analyzer:
Specifications
| Automated or Manual Spectrum Analysis | |
| Frequency Range: | 5 - 870 MHz |
| Dynamic Range: | >60 dB |
| Resolution Bandwidth: | 100 kHz |
| Reference Level: | TV from 15 dBuV to 125 dBuV |
| or -45 to +66 dBmV | |
| -93 to +18 dBm | |
| Marker Frequency: | 5-870 MHz |
| Marker Analog or Digital: | Automatic |
| Bar Scan: | 19 to 120 channels (selectable |
| Storage of Bar Scan: | Up to 20 pictures |
| Analog Measurements | |
| Frequency Band: | TV & Radio 5-870 MHz |
| Frequency Resolution: | 62.5 kHz |
| Input Impedance: | 75 ohms |
| Dynamic Range Meas.: | 15 dBuV to 125 dBuV |
| or -45 to 65 dBmV | |
| or -98 to +16 dBm | |
| Measurement Resolution: | 0.1 dB |
| Level Meas. Accuracy: | 1 dB typical (2 dB max.) |
| A/V Ratio: | 1.5 dB typical (2 dB max.) |
| C/N Ratio: | 2 dB typical (4 dB max.) |
| Meas. Filter Band: | 100 kHz @ -3 dB |
| Channel Plan Memory: | 600 memory positions |
| Leakage: | band 115-140 MHz |
| Ingress: | band 5-65 MHz |
| Digital Measurement (Emulated digital measurement for 8-VSB, QAM64-12-256) | |
| Frequency Band: | 14-870 MHz |
| Power Meas. Band: | from 25 dBuV to 116 dBuV |
| or -35 to +56 dBmV | |
| -85 to +8 dBm | |
| BER Measurement: | bBER up to 2 x 10-8 |
| Digital Signal Quality: | PASS-MARG-FAIL |
| Based on C/N measurement | |
| Multiplex Flatness: | Digital-Degraded-Analog |
| Digital Power Limit | Indicates signal power too high or too low |
| General Specifications | |
| Voltmeter Function: | AC, DC, 0 to 100 V |
| Channel plan master copy function: | (optional via PC) |
| Power Supply: | - Built in NI-CD rechargeable battery: 8 batteries |
| -External power supply: 17 Vac or 20 Vdc 1A | |
| -AC/DC adapter: 120 V | |
| Battery Duration (25º C: | 4-6 hours in analog mode |
| 3-4 hours in digital mode | |
| Size: | 11.8" x 4.33" x 2.36" (HWD) |
| Weight: | 2.7 lb. |
| Download Port: | RS232 standard serial port |
| Display: | 128 x 128 pixels, 2.5" square |
| mailto:sales@sencore.com | |
| phone 1.800.736.2673 | International 1.605.339.0100 |