| MEASUREMENT
SPECIFICATIONS
Serial
Signals
Amplitude -
INPUT SIGNAL MAXIMUM LIMITS: ±10 V. MEASUREMENT RANGE:
±1.5 V. RIPPLE MEASUREMENT RANGE (Vrp): <1.5 V. Vrp
FREQUENCY RANGE: 0 to 10 kHz. MEASUREMENT RESOLUTION:
12 mV. TEST OUTPUT FOR MEASUREMENTS: Vpp and Vrp identical
value to voltage measured at 75 Ohms.
Jitter
- PARALLEL SIGNAL
JITTER RANGE: ±7.5 ns. SERIAL SIGNAL JITTER RANGE: ±1.5
ns. SERIAL SIGNAL JITTER RESOLUTION: 40 pS +10 pS with
10 m of cable. PARALLEL SIGNAL JITTER BANDWIDTH: 1.4
kHz. PARALLEL TEST OUTPUT JITTER: 100 mV/ns at 75 Ohms.
SERIAL TEST OUTPUT JITTER: 300 mV/ns at 75 Ohms. MISCELLANEOUS
- MON OUTPUT:
720 mV at 75 Ohms, DC component not transmitted. CLOCK
OUTPUT: Parallel signal clock 400 mVpp at 75 Ohms, DC
component not transmitted.
Measurements
Common To Serial And Parallel Signals - PREAMBLE
ERROR DETECTION: The analyser has a "hard" preamble
detector, which allows detection of a preamble error
on the 4 least significant bits. TEST OUTPUT LEVELS
FOR DISPLAY OF RESERVED CODES AND TRS ERRORS: 700 mV
at 75 Ohms.
Major Alarm
Threshold
SERIAL SIGNAL:
Signal absence or TRS word error frequency of more than
10 errors in 500 ms. PARALLEL SIGNAL: When clock/data
phase measurement shows clock phase to be outside the
range of ±11 nS. SECONDARY ALARM THRESHOLD: When one
parameter falls outside specifications. SERIAL LINK:
Adjustable from 2,400 to 19,200 Baud; delivered set
at 9,600 Baud. OTHER PARAMETERS: 8 bits, 1 start bit,
no parity.
Parallel
Signals
Amplitude - INPUT
SIGNAL MAXIMUM LIMITS: 0 V to -5.2 V. CLOCK SIGNAL MEASUREMENT
RANGE: -1.29 V ± 1.29 V. VAV DATA MEASUREMENT RANGE:
-1.29 V ±1.29 V. MEASUREMENT RESOLUTION: 11mV. MEASUREMENT
PRECISION: ±25 mV. TEST OUTPUT FOR VPP AND VRP MEASUREMENTS:
Vpp value identical to the measured signal. VAV: Displayed
value is measured value +1.79V.
Clock/Data
Phase - PRECISION:
±1.5 ns. TEST OUTPUT LEVEL: 700 mV at 75 Ohms.
TEST
PATTERN GENERATOR SPECIFICATIONS
Outputs
- 1 parallel digital output to CCIR Rec. 656, 2
270 Mb/s serial digital outputs at 75 Ohms.
Calibrated
errors on parallel signal - Level
errors can be introduced in the clock signal and on
the two most significant bits. PEAK-TO-PEAK LEVEL ERROR:
Vpp minimum = 0.25 V, ±0.1 V, Vpp nominal = 1.1 V, ±0.1
V. AVERAGE LEVEL ERROR: Vav min = 1.60 ±0.05 V, Vav
nom = 1.29 ±0.05 V, Vav max = -0.95 ±0.05 V. RIPPLE
VOLTAGE ERROR: 1V ±10% at 122 Hz or 7812 Hz. CLOCK/DATA
PHASE ERROR: -12 ns to +16 ns in steps of 4 ns, ±2 ns
precision for each step.
Errors
common to parallel and serial signals - Ability
to introduce reserved codes as well as errors in TRS
word and preambles. JITTER ERROR: 4 ±1 ns at 122 Hz
or 976 Hz.
Patterns
- PATTERNS AVAILABLE: 34. OF WHICH: CCIR - 14 patterns,
user configurable - 2 patterns, others - 18 patterns.
ACCESSIBLE VIA FRONT-PANEL CONTROLS: 16 patterns. ACCESSIBLE
VIA SOFTWARE/SERVICE MODULE: 34 patterns. PATTERN 1:
75% colour bars. PATTERN 2: 100% colour bars. PATTERN
3: multi-burst. PATTERN 4: green (270 Mb/s serial test).
PATTERN 5: magenta (270 Mb/s serial test). PATTERN 6:
grey. PATTERN 7: black and white alternating at 0.1
Hz. PATTERN 8: end-of-lines pulses. PATTERN 9: black/white
ramp. PATTERN 10: yellow/grey ramp. PATTERN 11: grey/
blue ramp. PATTERN 12: cyan/grey ramp. PATTERN 13: grey/red
amp. PATTERN 14: Cb, Y, Cr, Y ramps. PATTERN 15: programmable
pattern. PATTERN 16: programmable pattern. PATTERN 17:
white end-of-line porches. PATTERN 18: blue end-of-line
porches. PATTERN 19: red end-of-line porches. PATTERN
20: yellow end-of-line porches. PATTERN 21: cyan line
end-of-line porches. PATTERN 22-34: grey.
GENERAL
SPECIFICATIONS
CONSTRUCTION:2U
19" rack mounting unit. DEPTH: 328 mm (13"). WEIGHT:
Basic unit - 5 kg (11 lbs), with all options - 6.2 kg
(13.64 lbs). AMBIENT TEMPERATURE RANGE: +5°C to +45°C.
ELECTRICAL
SPECIFICATIONS
POWER
SUPPLY: 105-130 V AC, 50-60 Hz (220 V Opt). MAXIMUM
CONSUMPTION: 50 watts (all optional modules included).
FUSE: 1.6 A (time-delay fuse).
|