SC3100 "AUTO TRACKER" Features

A complete waveform and circuit analyzing system in one instrument Auto-Tracking™ digital readout of waveform voltage and frequency with one probe connection
Integrated measurements of all circuit parameters provides fast troubleshooting answers Full performance, 100 MHz dual trace oscilloscope
Exclusive autoranged timebase and vertical attenuators eliminate wasted time Digital delta measurements to analyze every portion of any waveform
All functions microprocessor integrated for ease-of-use


SC3100 Condensed Specifications
Vertical Amplifiers - DISPLAY MODES: Channel A, inverted channel A (-A), channel B, dual trace (A&B), algebraic sum (A+B) or difference (B-A), vector (X-Y). CALIBRATION ACCURACY: ±3% at 1 kHz. FREQUENCY RESPONSE (100 MHz): AC coupled: ±3 dB of 1 kHz level from 10 Hz to 100 MHz, usable to 150 MHz. SENSITIVITY: 20 mV/div. to 200 V/div. with supplied 39G292 10X probe; 2 mV/div. to 20 V/div. with (optional) DP270 Direct Probe. MAXIMUM INPUT PROTECTION: Supplied 39G292 10X Probe: 2500 volts breakdown (DC + Peak AC).
Horizontal Sweep - SWEEP RATES: 100 milliseconds/division to 20 nanosecond/division. Autorange automatically selects sweep rate to show approximately 2-5 cycles of waveform. ACCURACY: ±3%.
Trigger Circuits - TRIGGER SOURCE: CH A, CH B, AC power line, or external. TRIGGER MODES: NORM, AUTO, TV.
Auto-TrackingTM Digital Tests - DC Volts: DCV FUNCTION: Provides direct reading of DC voltage on selected channel. ACCURACY: ±0.5% ±2 digits.
Peak-to-Peak Volts - VPP FUNCTION: Provides direct reading of peak-to-peak voltage on selected channel with either X10 or direct probes. ACCURACY: ±2% ±4 counts. FREQUENCY RESPONSE: ±0.5 dB from 20 Hz to 30 MHz,˛-3 dB at 100 MHz.
AC Volts - ACV FUNCTION: Calculates RMS sinewave value from PPV measurement. dBm FUNCTION: Calculates dBm measurement from PPV sinewave measurement, referencing 1 mW across 600 Ohms (0 dBm =.7746 volts RMS).
Frequency - Automatically displays the frequency of the signal on selected channel. RANGES: 10.00 Hz to 150 MHz. ACCURACY: .001% ±1 digit.
Delta Peak-to-Peak - Measures amplitude of intensified area on selected channel.
Delta Time - Measures time of intensified waveform portion.
1/Delta Time - Converts Delta Time reading to equivalent frequency.
Delta DC Volts - FUNCTION: Measures DC voltage level of marked waveform point in respect to ground using the PPV and DCV functions. MARKER: Fully adjustable over entire range of waveform.
Digital Meter Tests - Ohms FUNCTION: Provides in- or out-of-circuit ohms. RANGES: 0.00 to 100 M Ohms. ACCURACY: 0.2% ±2 digits.
Continuity Test - Provides audible tone of continuity. RANGE: 0 to 199 Ohms. Audible tone turns on if resistance is <10 Ohms and turns off if resistance is >15 Ohms, ±2 Ohms.
DC Current - Provides measurement of DC current. RANGES: .001 to 1.99 amp ACCURACY: 0.3% ±2 digits.
General - SIZE: 7.25" x 13.75" x 15" HWD (18.4 x 34.9 x 38.1 cm). WEIGHT: 25 lbs (9.33 kg.). POWER: 105 to 125 VAC, 50/60 Hz.